滚动至顶部

repeatable

Factory illustrations

How to Test for Leaks in Product Seals Without Contacting Water: The Principles and Limitations of Air Leak Testers

This article explains the principle behind airtightness testers, which detect product leaks by measuring changes in air pressure or flow rate within a sealed chamber. It also presents a case study of a road surveying instrument that measured 1 Pa at 15 kPa and passed a water immersion test with no bubbles, demonstrating that the two methods can be used for cross-validation. The article also emphasizes that pass/fail thresholds must be set according to standards, and that resolution is not equivalent to accuracy; airtightness testing is suitable for mass-production screening and traceability, while the water immersion method is better suited for visually locating leak points.

New Energy Electric Vehicles

A Comprehensive Guide to Power Battery Leak Testing: National Standard Updates, Testing Methods, and Selection Guidelines

This article focuses on the implementation of the new national standard GB 38031-2025 and systematically outlines the entire process of airtightness testing for power battery packs: It analyzes the fundamental differences between type testing and production line testing, compares the applicable scenarios for the four methods—direct pressure, differential pressure, flow-based, and helium leak testing—provides recommendations for selecting equipment for different components, and emphasizes that parameter settings must adhere to technical agreements. The paper also advocates for the objective evaluation of equipment through sample validation and repeatability testing, thereby offering a practical guide for production line acceptance.

Airtightness Testing_LED Lamps Case

When the same product is tested twice, the results get lower each time—it’s not a problem with the airtightness equipment; it’s a flaw in the method.

This article explains that the phenomenon of initially high data readings followed by a gradual decrease in airtightness testing is not due to instrument malfunction, but rather to an improper testing method. The root cause lies in the elastic deformation that occurs when the product is pressurized for the first time; if testing continues without sufficient depressurization and recovery, the stress release process in the material will be superimposed on the leakage values, resulting in a systematic drift in the data. Standard procedures require complete depressurization, allowing sufficient recovery time, controlling temperature, and ensuring fixture consistency; only under these conditions can the repeatability of the equipment be truly evaluated.

滚动至顶部